SELECA ist ein Tischanalysengerät, welches sowohl für die O2- als auch für die CO2-Messung geeignet ist. http://t.co/C7kJ7P34

MULTIPLEX
MULTIPLEX is a centralized O2 and CO2 analyser with a high precision microprocessor and a PC. O2 measurement is by a paramagnetic sensor. CO2 measurement is by an infrared sensor of latest generation.
The equipment works automatically and is able to analyse sequentially 48 cold rooms.
It can also be connected in a network withother analysers.
Using he programme ISOSOFT in the PC, with interfaces MULTIPLEX controls all the devices to maintain the room set-points
TECHNICAL FEATURES:
|
SYSTEM AUTOMATION - MULTIPLEX |
|||||
|
Technical data
|
| GAS TYPE | O2 | CO2 |
| MEASUREMENT RANGE | 0-25 % | *0-10 % |
| ACCURACY | 0,1 % | 0,1 % |
| WARM UP TIME | 5 min. | |
| GAS SAMPLING | pump | |
| MEASURMENT PRINCIPLE | paramagnetic cell | infrared |
| POWER SUPPLY | 220-240V. A.C. | |
| DIMENSIONS mm | 600x640x1970 | |
| WEIGHT | 180 Kg | |